Web Analytics Made Easy - StatCounter

Speed Measurement System Tenders

Get complete information related to latest Speed Measurement System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Speed Measurement System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Speed Measurement System Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :40126145 Due date: 05 May, 202505 May, 2025 2.62 Lacs
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s

corporations/Associations/Others

CTN :40126147 Due date: 05 May, 202505 May, 2025 2.62 Lacs
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s

CTN :40062013 Due date: 03 May, 202503 May, 2025 2.53 Crore
Tender For procurement and installation of different instruments for instrumentation of earth dam and spillway in deo irrigation project for the year 2025. - supply of fiberglass reinforced plastic (frp) make universal enterprises an improved venturi plate conformed to is: 9108 for accurate measurement of water flowing through channels comprising of masonry construction provided with pre-fabricated glass fiber lining on both sides, a side chamber provided in one side masonry wall of the said flume on the upstream side, a pipe provided at the bottom of the chamber connecting the said chamber with the water flowing through the notch, a float means provided in the said chamber, enabling recording the rising or falling level of water in the said chamber such as a scale provided in the said chamber, moulded engraved gauge marking in lit/sec and also in centimeter including moulded and engraved discharge table, capacity marking, flow direction, m.s pipe stiffeners, hold fasts, sand treatment on the backside of plate but excluding gst as per the instruction of engineer-in-charge etc. complete, inside spillway foundation gallery - 15 lit./sec. v-notch, seepage drain - 90 lit./sec. v-notch, calibration marks:- supply of polymers composites improved calibration marks make universal enterprises with contact molding process, both side finish, m.s. strip embedded inside, engraved and molded marking for bands and figures covered with radium and covered with two coats of polyurethane for surface protection with marking in reduced levels, sill, fsl, frl, mwl but excluding gst as per the instruction of engineer-in-charge etc. complete, supply vw up-lift pressure meter provision for connected to das make : aimil ltd. uplift pressure meters are used for measuring and recording of uplift pressures acting in foundations of concrete/masonry dams. vibrating wire type uplift pressure meter : range: 0.2 mpa to 5.0 mpa./7ksc accuracy: 0.5 -1 % fs. temp limit: - 10 to 70 deg c. coil resistance: 140 - 160 ohm thermistor: ysi-44005 or equivalent. material: stainless steel cable: 1m, 4-core borehole for uplift pressure meter at foundation gallery (inside spillway) should be straight from foundation level and clear. proposed location : inside spillway foundation gallery in overflow section: 7 no. non overflow section: 2 no. purpose: uplift water pressure measurement. (but excluding gst), supply automatic seepage measuring system make : aimil ltd / sysgeo italy or equivalent vibrating wire water leakage measuring systems are used for measuring water leakage and flow in dam galleries by installing v notch weir coupled with vibrating wire sensor for remote monitoring of water leakage. sensor type: sensor : vibrating wire precision water level sensor range: 300mm resolution: 0.025%fs material : stainless steel excitation : sweep or pluck assembly: v.w. type sensors enclosed in an environmental proof fibre glass box. splicing kit & adhesive required accessories. proposed location : inside spillway foundation gallery: 1 no. toe drain: 1 no. (drainage outlet) purpose: seepage water measurement in liter per second (but excluding gst), supply data logger or data acquisition system aimil make dt85g with cem20 or ace s korea analog channels 16 analog input channels each channel is independent and supports: one isolated 3-wire or 4-wire input, or two isolated 2-wire inputs, or three common referenced 2-wire inputs. expansion requires optional cem20 sampling integrates over 50/60hz line period for accuracy and noise rejection maximum sample speed: 40hz effective resolution: 18 bits linearity: 0.01% common mode rejection: >90db line series mode rejection: >35db vibrating wire frequency range: 500 to 5khz coil resistance: 50 to 200 stimulation method: single pulse pluc digital channels 8 bi-directional channels input type: 8 logic level (max 20/30v) output type: 4 with open drain fet(max: 30v, 100ma) 4 with logic output alarms power supply , sim card will be in your scope. propo
 Loading, Please wait...

Connect us via What's Up